Validation of an oxygen-wash in/wash out technique for determination of FRC

Autor/innen

Abstract

The routine determination of the functional residual capacity (FRC) was to assess the progress and to monitor therapeutic procedures to ventilated patients benefit. It was measured by means LUFU FRC (LUFU FRC) in 20 healthy volunteers when sitting or lying, and in 15 lung disease patients in a sitting position with the determined by helium dilution FRC (He-FRC) and with the determined by body plethysmography intrathoracic gas volume (ITGV ) compared. In each case four LUFU FRC values (FiO2 change of 0.21 to 0.5 and back to 0.21 and from 0.21 to 1.0 and back to 0.21) and two He-FRC and two were ITGV values bestimmt.Bei the volunteers had mean LUFU FRC sitting at 3.26 L, the He-FRC sitting at 3.11 L and 3.08 L ITGV in while the values lying on 2.29 L in LUFU FRC and 2.00 L reduced in the He-FRC. The correlation between LUFU FRC and FRC He gave a sitting R2 of 0.84 and lying a R2 of 0.80. Average arose for sitting and lying measurements a correlation of R2 = 0.87. Between LUFU FRC and ITGV was the correlation R2 = 0.81 and was between He-FRC and ITGV the R2 = 0.82. The comparison of the FiO 2 of 0.29 and 0.79 in the LUFU FRC showed together for lying and sitting position a correlation of R2 = 0.96. From the comparison of the determined by Sauerstoffeinatmung and Sauerstoffauswaschung average FRC an R2 = 0.95 resulted. The comparison of the first and second measurement revealed in all methods of determination from 0.74 to 0.96.

Literaturhinweise

Baker AB, Restall R (1983) Changes in residual volume following oxygen breathing. Br J Anaesth 55:817-823

Bankstahl A (1971) Vergleichende Untersuchungen des Residualvolumens bei Kindern und Jugendlichen mit der Ganzkörperplethysmographie und der Heliummethode. Pneumonologie 144:328-343

Brismar B, Hedenstierna G, Lundquist H, Strandberg A, Svensson L, Tokics L (1985)Pulmonary densities during Anesthesia with muscular relaxation - a proposal of atelec¬tasis. Anesthesiology 62:422-428

Corbeel LJ (1969) Comparison between measurements of functional residual capacity and thoracic gas volume in chronic obstructive pulmonary diseases. In: Prog Resp Res, Vo14, DuBois AB and Van de Woestijne KP eds., pp. 194-204. Karger, Basel/New York, 1969.

Fretschner R, Oeusch H, Weitnauer A, Brunner JX (1993) A simple method to estimate functional residual capacity in mechanically ventilated patients. Intensive Care Med 19:372-376

Froese AB, Bryan C (1974) Effects of anesthesia and paralysis on diaphragmatic mechanics in man. Anesthesiology 41:242-255

Hedenstierna G, McCarthy G, Bergström M (1976) Airway closure during mechanical ventilation. Anesthesiology 44: 114-123

Hedenstierna G (1993) The recording of FRC - is it of importance and can it be made simple? Intensive Care Med 19:365-366

Hewlett AM, Hulands GH, Nunn JF, Heath J (1974) Functional residual capacity during anaesthesia. 11. Spontaneous respiration. Br J Anaesth 46:486-494

Hylkema BS, Barkmeijer-Degenhart P, van der Mark TW, Peset R, Sluiter HJ (1982) Measurement of functional residual capacity during mechanical ventilation for acute

respiratory failure. Chest, 81 :27-30

Katz JA, Ozanne GM, Zinn SE, Fairley HB (1981) Time course and mechanics of lung¬volume increase with PEEP in acute pulmonary failure. Anesthesiology 54:9-16

Lum91 Lumb AB, Nunn JF (1991) Respiratory function and ribcage contributions to ventilation in body positions commonly used during anesthesia. Anesth Analg 73:422-426

Mitchell RRO, Wilson RMO,OHolzapfel L, OBenis AM, Osborn JJ (1982) Oxygen wash-in method for monitoring functional residual capacity. GritDare OMed 00010:529-533

Nunn JF, Williams IP, Jones JG, Hewlett AM, Hulands GH, Minty BD (1978) Detection and reversal of pulmonary absorption collapse. Br J Anaesth 50:91-99

Quanjer PH, Tammeling GJ, Gotes JE, Pedersen OF, Peslin R, Yernault JG (1993) Lung volume and forced ventilatory flows. Report of the Working Party on Standardization of Lung Function Tests. European Gommunity for Steel and Goal. Official statement of the European Respiratory Society. Eur Respir J 6 (SuppI16):5-40

Ramachandran P, Fairley HB (1970) Ghanges in functional residual capa city during respiratory failure. Ganad Anaesth Soc J 4:359-369

Reber A, Engberg G, Wegenius G, Hedenstierna G (1996) Lung aeration. The effect of pre-oxygenation and hyperoxygenation during total intravenous anaesthesia. Anaesthesia 51 :733- 737

Rung I, Kämmerer H, Klaschik E (1980) Eine einfache Heliumverdünnungsmethodezur Bestimmung der funktionellen Residualkapazität beim maschinell beatmeten Kranken. Anaesthesist 29: 148-151

Schaanning CG, Gulsvik A (1973) Accuracy and Precision of Helium Dilution Technique and Body Plethysmography in Measuring Lung Volumes. Scand J LabInvest 32:271-277

Tokics L, Hedenstierna G, Strandberg A, Brismar B, Lundquist H (1987) Lung collap¬se and gas exchange during general anaesthesia: Effects of spontaneous breathing, muscle paralysis, and positive end-expiratory pressure. Anaesthesiology 66: 157-167

Wauer HJ, Lorenz BA, Kox WJ (1998) FRG-Messung bei beatmeten Intensivpatienten. Eine Standortbestimmung. Anaesthesist 47:844-855

Weissmann 0, Reissmann H, Maisch S, Füllekrug B, Schulte am Esch J (2003) Determination of Functional Residual Gapacity with an Oxygen washinlwashout; Technical Description and Evaluation.

Wrigge H, Sydow M, Zinserling J, Neumann P, Hinz J, Burchardi H (1998) Determination of functional residual capacity (FRC) by multibreath nitrogen washout in a lung model and in mechanically ventilated patients. Intensive Care Med 24:487-493

Baldwin E. deF.; Cournand A.; Richards D.W.: Pulmonary insufficiency. Medicine, 27, 243-278. Baltimore (1948)

Black AM.S.; Hahn C.E.W.; Maynard P.; Scott I.L.: Measurement of lung volume by multiple indicator dilution. Br. J. Anaesth. (1984), 56, 289-298

DuBois A; Botelho S.Y.; Bedell G.N.; Marshall R2.; Comroe J.H.: A rapid plethysmographic method für measuring thoracic gas volume: A comparison with a nitrogen washout method for measuring functional residual capacity in normal subjects. J. Clin. Invest., 35, 322-326 (1956)

Boutellier U.; Farhi L.E.: A fundamental problem in determining functional residual capacity or residual volume. Special communications. American Physiological Society: 1810-1813 (1986)

Brown R2.; Hoppin F.G.; Ingram R2.H.; Saunders N.A; McFadden E.R2.: Influence of abdominal gas on the Boyle's law determination of thoracic gas volume. American Physiological Society: 469-473 (1978)

Gook C.D.; Hamann J.F.: Relation of jung vojumes to height in healthy persons between the ages of 5 and 38 years. The Journal of Pediatrics: 710-714 (Nov. 1961)

Craig D.B.; Wahba W.M.; Don H.: Aiway closure and lung vojumes in surgical positions. Canad. Anaesth. Soc. J., vol. 18, no.1: 92-99 (Januar 1971)

Craig D.; Wahba W.M.; Don H.F.; Couture J.G.; Becklake M.R2.: "Closing vojume" and ist relationship to gas exchange in seated and supine positions. Journal of Applied Physiojogy, Vol. 31, No. 5: 717-721 (November 1971)

Dantzker D.R2.; Wagner P.D.; West J.B.: Instability of jung units with low Va/Q ratio during 02 breathing. Journal of Appjied Physiology, Vol. 38: 886-895 (Mai 1975)

Darling R2.C.; Cournand A.; Mansfiejd J.S.; Richards D.W.: Studies on the intrapulmonary mixture of gases I. Nitrogen elimination from blood and body tissues during high oxygen breathing. J. Clin. Invest., 19: 591-597 (12. März 1940)

Darling R2.C.; Cournand A.; Mansfield J.S.; Richards D.W.: Studies on the intrapulmonary mixture of gases 111. An open circuit method für measuring residual air. J. Clin. Invest., 19: 609¬618 (12. März 1940)

Darling R2.C.; Cournand A.; Mansfiejd J.S.; Richards D.W.: Studies on the intrapujmonary mixture of gases V.Fürms of inadequate ventilation in normal and emphysematous lungs, analysed by means of breathing pure oxygen. J. Clin. Invest., 23: 55-67 (6. Mai 1944)

Fowler W.S.: Lung function studies. IV. Postural changes in respiratory dead space and functional residuaj capacity. J. Cjin. Invest., 29: 1437-1438 (24. Juli 1950)

Grimby G.; Söderholm B.: Spirometric Studies in Normaj Subjects. 111. Static Lung Volumes and Maximum Voluntary Ventilation in Adults with a Note on Physicaj Fitness. Acta Medica Scandinavica. Vol. 173, fasc. 2: 199-206 (1963)

Hedenstierna G.; McCarthy G.: Mechanics of breathing, gas distribution and functional residual capacity at different frequencies of respiration during spontaneous and artificial ventilation. Br. J. Anaesth. (1975), 47: 706-712

Hedenstierna G.; Järnberg; Gottlieb: Thoracic gas volume measured during anesthesia. Anesthesiology, V 55, No 4: 439-443 (Oktober 1981)

Heldt G.P.; Peters R2.M.: A simplified method to determine functional residual capacity during mechanical ventilation. Clinicallnvestigations. Chest, 74: 492-496 (November 1978)

Hickam J.B.; Blair E.; Frayser R2.: An open-circuit method für measuring functional residual capacity and defective intrapulmonary gas mixing. J. Clin. Invest., 33: 1277-1286 (Mai 1954)

Hurtado A; Fray W.W.: Studies of total pulmonary capacity and ist subdivisions. 111. Changes with body posture. J. Clin. Invest., 12: 825-832 (April 1933)

Jonmarker C.; Jansson L.; Jonson B.; Larsson A.; Werner 0.: Measurement of functional residual capacity by sulfur hexaflouride washout. Anesthesiology, 63: 89-95 (1985)

Katz J.A; Ozanne G.M.; Zinn S.E.; Fairley H.B.: Time course and mechanics of lung-volume increase with PEEP in acute pulmonary failure. Anesthesiology, 54: 9-16 (1981)

Lundin G.: Nitrogen Elimination during oxygen breathing. Acta Physiol. Scandinavica Suppl. 111,30: 131-143 (1953)

Meneely G.R2.; Kaltreider N.L.: The volume of the lung determined by helium dilution. Description of the method and comparison with other procedures. J. Clin. I nvest. , 28: 129-139 (Juli 1943)

Ozanne G.M. Zinn S.E.; Fairley H.B.: Measurement of functional residual capacity during mechanical ventilation by simultaneous exchange of two insoluble gases. Anesthesiology, 54: 41 3-41 7 (1981)

Paloski W.H.; Newell J.C.; Gisser D.G.; Stratton H.H.; Annest S.J.; Gottlieb M.E.; Shah D.M.: A system to measure functional residual capacity in critically ill patients. Critical care medicine: 342-346 (April 1981)

Rossi A.; Polese G.; Brandi G.; Conti G.: Intrinsic positive end-expiratory pressure (PEEPi). Intensive care medicine (1995) 21: 522-536

Sjästrand U.H.; Lichtwarck-Aschoff M.; Nielsen J.B.; Marksträm A; Larsson A; Svensson B.A; Wegenius G.A; Nordgren K.A: Different ventilatory approaches to keep the lung open. Intensive Care Med. (1995) 21: 310-318

Stokke 1.; Hensell.; Burchardi H.: Eine einfache Methode für die Bestimmung der funktionellen Residualkapazität während Beatmung. Anaesthesist (1981) 30: 124-130

Sutherland P.W.; Katsura 1.; Milic-Emili J.: Previous volume history of the lung and regional

distribution of gas. Journal of Applied Physiology, Vol. 25, No 5: 566-574 (November 1968)

deVries WoR2.; Luijendijk S.G.Mo; Zwart A.: Helium and sulfur hexaflouride washout in asymetric lung models. American Physiological Society: 1122-1130 (1981)

Veröffentlicht

2016-04-20

Zitationsvorschlag

Schedler, O. (2016). Validation of an oxygen-wash in/wash out technique for determination of FRC. Berlin Medical Journal, 1(1). Abgerufen von http://bmjs.me/index.php/BMJ/article/view/8